4 * This file is part of BeRTOS.
6 * Bertos is free software; you can redistribute it and/or modify
7 * it under the terms of the GNU General Public License as published by
8 * the Free Software Foundation; either version 2 of the License, or
9 * (at your option) any later version.
11 * This program is distributed in the hope that it will be useful,
12 * but WITHOUT ANY WARRANTY; without even the implied warranty of
13 * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
14 * GNU General Public License for more details.
16 * You should have received a copy of the GNU General Public License
17 * along with this program; if not, write to the Free Software
18 * Foundation, Inc., 51 Franklin St, Fifth Floor, Boston, MA 02110-1301 USA
20 * As a special exception, you may use this file as part of a free software
21 * library without restriction. Specifically, if other files instantiate
22 * templates or use macros or inline functions from this file, or you compile
23 * this file and link it with other files to produce an executable, this
24 * file does not by itself cause the resulting executable to be covered by
25 * the GNU General Public License. This exception does not however
26 * invalidate any other reasons why the executable file might be covered by
27 * the GNU General Public License.
29 * Copyright 2004, 2005, 2009 Develer S.r.l. (http://www.develer.com/)
33 * \brief Thermo-control driver.
35 * This module implements multiple thermo controls, which is the logic needed to try
36 * keeping the temperature of a device constant. For this module, a "device" is a black box
37 * whose temperature can be measured, and which has a mean to make it hotter or colder.
38 * For instance, a device could be the combination of a NTC (analog temperature reader) and
39 * a Peltier connected to the same physic block.
41 * This module relies on a low-level driver to communicate with the device (implementation
42 * of the black box). This low-level driver also controls the units in which the temperature
43 * is expressed: thermo control treats it just as a number.
47 * \author Giovanni Bajo <rasky@develer.com>
48 * \author Francesco Sacchi <batt@develer.com>
50 * $WIZ$ module_name = "thermo"
51 * $WIZ$ module_depends = "timer", "ntc"
52 * $WIZ$ module_configuration = "bertos/cfg/cfg_thermo.h"
53 * $WIZ$ module_hw = "bertos/hw/hw_thermo.h", "bertos/hw/thermo_map.h"
59 #include "hw/thermo_map.h"
63 void thermo_init(void);
67 * Set the target temperature at which a given device should be kept.
70 * \param temperature Target temperature
72 void thermo_setTarget(ThermoDev dev, deg_t temperature);
74 /** Start thermo control for a certain device \a dev */
75 void thermo_start(ThermoDev dev);
77 /** Stop thermo control for a certain device \a dev */
78 void thermo_stop(ThermoDev dev);
80 /** Clear errors for channel \a dev */
81 void thermo_clearErrors(ThermoDev dev);
83 /** Return the status of the specific \a dev thermo-device. */
84 thermostatus_t thermo_status(ThermoDev dev);
87 * Return the current temperature of a device currently under thermo
91 * \return Current temperature (Celsius degrees * 10)
93 deg_t thermo_readTemperature(ThermoDev dev);
96 #endif /* DRV_THERMO_H */