Connect ATmega64 to correct analog ground.
authorbatt <batt@38d2e660-2303-0410-9eaa-f027e97ec537>
Tue, 23 May 2006 15:17:10 +0000 (15:17 +0000)
committerbatt <batt@38d2e660-2303-0410-9eaa-f027e97ec537>
Tue, 23 May 2006 15:17:10 +0000 (15:17 +0000)
git-svn-id: https://src.develer.com/svnoss/bertos/trunk@629 38d2e660-2303-0410-9eaa-f027e97ec537

app/triface/doc/schematics/TRIFACE.DSN
app/triface/doc/schematics/triface.opj

index 9bfc8e973c09a755bcc07bd31dac6e47ec57eb4e..d7dc61000259d32884eb6f603da2785522426eee 100755 (executable)
Binary files a/app/triface/doc/schematics/TRIFACE.DSN and b/app/triface/doc/schematics/TRIFACE.DSN differ
index e2b1081d49a604bc5ca0ec51bfc2583f60420ec6..9910e60b47505429af9bc89d66381377d20969a4 100755 (executable)
@@ -31,6 +31,9 @@
       (Type "Report")))\r
   (Folder "Referenced Projects")\r
   (PartMRUSelector\r
+    (GND_SIGNAL\r
+      (LibraryName "C:\ORCAD\ORCAD_10.5\TOOLS\CAPTURE\LIBRARY\CAPSYM.OLB")\r
+      (DeviceIndex "0"))\r
     (JUMPER\r
       (FullPartName "JUMPER.Normal")\r
       (LibraryName "D:\ORCAD\TOOLS\CAPTURE\LIBRARY\CONNECTOR.OLB")\r
@@ -74,9 +77,6 @@
       (FullPartName "MAX690.Normal")\r
       (LibraryName "C:\PROGRAMMI\ORCAD\TOOLS\CAPTURE\LIBRARY\MISCPOWER.OLB")\r
       (DeviceIndex "0"))\r
-    (GND_SIGNAL\r
-      (LibraryName "C:\ORCAD\ORCAD_10.5\TOOLS\CAPTURE\LIBRARY\CAPSYM.OLB")\r
-      (DeviceIndex "0"))\r
     (PORTLEFT-L\r
       (LibraryName "C:\ORCAD\ORCAD_10.5\TOOLS\CAPTURE\LIBRARY\CAPSYM.OLB")\r
       (DeviceIndex "0"))\r
   (GlobalState\r
     (FileView\r
       (Path "Design Resources")\r
-      (Path "Design Resources"\r
-         "c:\documents and settings\batt\desktop\devtools\devlib\app\triface\doc\schematics\triface.dsn")\r
-      (Path "Design Resources"\r
-         "c:\documents and settings\batt\desktop\devtools\devlib\app\triface\doc\schematics\triface.dsn"\r
-         "TRIFACE BOARD")\r
-      (Path "Outputs")\r
-      (Select "Design Resources"\r
-         "c:\documents and settings\batt\desktop\devtools\devlib\app\triface\doc\schematics\triface.dsn"\r
-         "TRIFACE BOARD" "POWER SUPPLY"))\r
+      (Path "Design Resources" ".\triface.dsn")\r
+      (Path "Design Resources" ".\triface.dsn" "TRIFACE BOARD")\r
+      (Path "Outputs"))\r
     (HierarchyView)\r
     (Doc\r
       (Type "COrCapturePMDoc")\r
       (Frame\r
-        (Placement "44 2 3 -1 -1 -4 -23 0 312 0 463"))\r
-      (Tab 0)))\r
+        (Placement "44 0 1 -1 -1 -4 -23 0 312 0 463"))\r
+      (Tab 0))\r
+    (Doc\r
+      (Type "COrSchematicDoc")\r
+      (Frame\r
+        (Placement "44 2 3 -1 -1 -4 -23 44 1084 44 516")\r
+        (Scroll "0 0")\r
+        (Zoom "100")\r
+        (Occurrence "/"))\r
+      (Path\r
+         "C:\DOCUMENTS AND SETTINGS\BATT\DESKTOP\DEVTOOLS\DEVLIB\APP\TRIFACE\DOC\SCHEMATICS\TRIFACE.DSN")\r
+      (Schematic "TRIFACE BOARD")\r
+      (Page "CPU")))\r
   (MPSSessionName "batt"))\r